ARTICLES

Filter  
Active filters 0
Remove
  

Refine your searches by:

Collections
Education
Agronomy and forestry
Biology
Medicine / Sub specialtie
Research
Technology
Medicine / Pharmacology
Pure sciences
Environment
Food and nutrition
all records (74)

Languages
English
Portuguese
Spanish
German
French

Countries
Indonesia
Brazil
USA
Ukraine
Portugal
Poland
Turkey, Turkish Republic
South Africa
India
Russia
all records (69)

Years
2023
2022
2021
2020
2019
2018
2017
2016
2015
2014
all records (24)

Filter  
 
18.843  Articles
1 of 1.885 pages  |  10  records  |  more records»
The purpose of this paper is to perform dosimetric verification (in-phantom) of dose distributions calculated with treatment planning system (TPS) by using  2D chamber array device in HDR brachytherapy. HDR brachytherapy treatment plans’dose distr... see more

AbstractBackground: Volumetric modulated arc therapy (VMAT) is the standard of care for many clinical indications, but should only be considered with proper technical support and quality assurance (QA) in place. Despite the high accuracy of VMAT systems, ... see more

The first part of this study was about measurement of dosimetric parameters for small photon beams to be used as input data for treatment planning computer system (TPS) and to verify the dose calculated by TPS in Stereotactic Radiosurgery (SRS) procedure.... see more

This paper purpose to analyze the effectiveness of the management of Islamic based lecturer competencies to create quality tertiary institutions through strengthening the integration of lecturer characters by strengthening academic dan spiritual character... see more

Background: Radiation-sensitive polymer gels are among the most promising three-dimensional dose verification tools and tissue-like phantom developed to date.Objective: The aim of this study is an investigating of percentage depth dose enhancement within ... see more

Background: Accelerated partial breast irradiation via interstitial balloon brachytherapy is a fast and effective treatment method for certain early stage breast cancers however skin, chest wall and Lung doses are correlated with toxicity in patients trea... see more

Radiation dose assessment to determine the potential of radiological impacts of various installations within nuclear facility complex is necessary to ensure evironmental and public safety. A simple generic model-based method for calculating radiation dose... see more

Continuous gantry motion, continuous beam modulation, and variable dose rate are used in volumetric modulated arc therapy (VMAT) to obtain highly conformal radiation therapy dose distributions. Several errors during daily radiation therapy treatment can b... see more

Background: The software used by treatment planning systems (TPS) plays an important role for treatments using radiation. The accuracy of the calculated dose in radiation treatments depends on the assumptions made by the TPS. In this study, we summarize o... see more

1 of 1.885 pages  |  10  records  |  more records»