ARTICLES

Filter  
Active filters 0
Remove
  

Refine your searches by:

Collections
Medicine / Anatomy
Medicine / Sub specialtie
Public health
Medicine / Dentistry
Pure sciences
Medicine / Physiology
Research
Mechanical Engineering
Social Sciences
Medicine / Pharmacology
all records (38)

Languages
English

Countries
Canada
Brazil
Indonesia
USA
Nepal
Argentina
Macedonia
Pakistan
Ukraine
Poland
all records (27)

Years
2022
2021
2020
2019
2018
2017
2016
2015
2014
2013
all records (18)

Filter  
 
164  Articles
1 of 17 pages  |  10  records  |  more records»
There are several important technical points that need to be observed when using an intramedullary nail to fix diametaphyseal fractures of femur and tibia. We aimed to describe a technique using 3.0-mm K wires, which act like Poller screws, in conjunction... see more

We present the outcome of four-corner wrist arthrodesis using two headless compression screws for fixation. The study group consisted of 27 patients who underwent arthrodesis from 1998 through 2007. Data on demographic parameters, diagnosis, range of moti... see more

The purpose of this study was to compare the period of union, functional outcomes and complications of patients with femoral neck fractures treated with percutaneous cannulated screws versus dynamic hip screw (DHS) and antirotational screwWe enrolled 160 ... see more

The purpose of this retrospective study was to evaluate the outcome of headless screws and Mini-plate for treating Type B3 fractures of distal humerus. Seventeen patients with type B3 fracture were included and divided into headless screws group and Mini-... see more

The purpose of this retrospective study was to evaluate the outcome of headless screws and Mini-plate for treating Type B3 fractures of distal humerus. Seventeen patients with type B3 fracture were included and divided into headless screws group and Mini-... see more

The purpose of this study was to compare the period of union, functional outcomes and complications of patients with femoral neck fractures treated with percutaneous cannulated screws versus dynamic hip screw (DHS) and antirotational screwWe enrolled 160 ... see more

We present the outcome of four-corner wrist arthrodesis using two headless compression screws for fixation. The study group consisted of 27 patients who underwent arthrodesis from 1998 through 2007. Data on demographic parameters, diagnosis, range of moti... see more

There are several important technical points that need to be observed when using an intramedullary nail to fix diametaphyseal fractures of femur and tibia. We aimed to describe a technique using 3.0-mm K wires, which act like Poller screws, in conjunction... see more

1 of 17 pages  |  10  records  |  more records»