ARTICLE
TITLE

High Sensitive Troponin I and Extended Range C-Reactive Protein as Markers to Predict Cardiotoxicity in Locally Advanced Breast Cancer with Neoadjuvant CAF (Cyclophoshpamide, Adriamycin/Doxorubicin, 5Fluorouracil) Therapy

SUMMARY

The limitation of echocardiography to measure chemotherapy cardiotoxicity at left locally advanced breast cancer with large ulcer is still serious problem. HsTnI and erCRP are biomarkers to detect cardiotoxicity that are cheap, easy to examine and available at Dr.Soetomo Hospital Surabaya. This study was to compare HsTnI, erCRP and echocardiography as cardiotoxicity predictors in locally advanced breast cancer with neoadjuvant CAF therapy. This study used one group pretest and posttest design among 23 locally advanced breast cancer patients. All patients underwent echocardiography, HsTnI, and erCRP examinations before and after 3 times chemotherapy and compared. The average age was 49.78±8.7. Statistically significant decrease in LVEF was found after treatment (67.98%±4.06 and 64.07%±3.53, p=0.000). HsTnI was significantly increased after treatment (0.007 µg/mL±0.004 and 0.043 µg/mL±0.051 p=0.000). erCRP was significantly decreased after treatment (1.043mg/dL±0.913 and 0.573mg/dL±0.444 p=0.044). Decreased LVEF and increased HsTnI was compared by its cardiotoxic cut-off. HsTnI was significantly better and faster to detect cardiotoxicity (0.033±0.051 p=0.002). In conclusion, strong correlation is present in the detection of cardiotoxicity between HsTnI and LVEF. HsTnI is faster than echocardiography, and could be alternative diagnostic to detect early cardiotoxicity.

 Articles related

Volodymyr Bubalo    

Introduction. Today in the world there is a tendency towards an increase in the incidence of salmonellosis. As well as an increase in the proportion of antibiotic-resistant and various temperature regimes of the pathogen strains. This justifies the urgen... see more


Petikam lavudu,Avula Prameela Rani,Are Purna Chander,Chandra Bala Sekaran    

A simple and sensitive high performance liquid chromatographic method is developed for the estimation of bosentan in pharmaceutical dosage forms. Chromatographic separation of the drug was achieved with an Thermo Scientific C18 column (250 mm × 4.6 mm I.... see more


Abhay Kumar Pandey, Deepti Pandey    

Objective .Hearing deficit in newborns may go unnoticed leading to crucial handicap to language development and impaired socioacademic profiles.Early detection and intervention is of utmost importance as safeguard against the consequent healthcare burden... see more


Ashish Patil    

Novel, simple, rapid and reliable High-Performance Thin-Layer Chromatographic (HPTLC) methods were developed and validated for the analysis of Formoterol Fumarate Dihydrate (FFD) in bulk and in in-house tablet formulation. HPTLC quantitation of FFD was d... see more


Md. Amran Hossain, Dipu Rani Kundu, Tasnuva Sharmin, Mahfuza Maleque, Sharmin Reza Chowdhury    

A simple, sensitive and precise reverse phase high performance liquid chromatographic method has been developed for the estimation of Carvedilol in pharmaceutical preparations. Chromatographic determination was performed on a reversed phase C 18 column (... see more