Investigation the helical strut attached vena cava filter hemodynamic performance

SUMMARY

The hemodynamic performance of the Celect Platinum vena cava filter and the modified forms of it with helical flow inducer strut attachments were studied, possible positive and negative effects of it were assessed. In this respect, computational fluid dynamic analyses were done by Ansys Fluent 18. The modified models that are attached with single and double helical flow inducer struts were enhanced the central velocity and shear stress on the filter. Increased velocity and shear stress on the filter may eliminate short term thrombus build-up problems by breaking the big size particulates under the high shearing forces. The new struts may also contribute to the ability of the filter to capture smaller clots, as well as to dissolve them from being bigger. Increased shear stress in the vessel wall near the vena cava filter may be evaluated as the reduction of recirculation and clotting in this region and it could prevent the accumulation of clots. The increased shear stress on the filter and the velocity may cause the migration problem of it, design improvements could eliminate this problem. With the idea of this helical flow inducer attachment, it is seen that the filter efficacy increases, and the flow are normalized.

 Articles related

Igor Pankratov, Ivan Pavlenko, O. Pomazan, A. Omelchenko    

Recently the possibility of resonant excitation of pressure perturbation by external helical magnetic perturbations near the rotating plasma edge was shown taking into consideration the finite plasma conductivity. In present paper the influence of the sm... see more


Md Ikbal HOSSAIN, Mohammad Rashed Iqbal FARUQUE, Mohammad Tariqul ISLAM    

Cellular phones are used in the vicinity of a human head, which absorbs power from antenna radiation. This investigation analyzes the effects of antenna substrate materials on electromagnetic (EM) absorption in a human head. Antennas are used in analysis... see more


Akmal Sabarudin,Kanaga Kumari Chelliah,Hamzaini Abdul Hamid    

Intravenous urography (IVU) and unenhanced helical computed tomography (UHCT) urography are the two main procedures performed in the radiological investigation for urolithiasis (urinary stone). However, exposure to ionizing radiation is the mai... see more


Zhong Tang,Yaoming Li,Lizhang Xu,Francis Kumi    

The thorough investigation of both grain threshing and grain separating processes is a crucial consideration for effective structural design and variable optimization of the tangential flow threshing cylinder and longitudinal axial flow threshing cylinde... see more