ARTICLE
TITLE

GROUNDWATER FLOW SYSTEM OF BANDUNG BASIN BASED ON HYDRAULIC HEAD, SUBSURFACE TEMPERATURE, AND STABLE ISOTOPES

SUMMARY

ABSTRACT To recognize the groundwater flow system in the Bandung Basin, two main methods of regional groundwater flow delineation were employed: hydraulic heads and tracers. Two different environmental tracers, i.e. subsurface temperature and stable isotope were applied. The measured temperatures and stable isotope compositions from 19 observation wells lead  to the recognition of three types of flow systems within the Bandung Basin i.e., shallow, intermediate and deep groundwater flow system. The recharge area is located in the hills and upland which form the periphery of the plain. The summit area of the southern mountainous complex might have represented the highest recharge area No indication was found for water being recharged at higher elevation in the northern part of the basin which means the recharged water in the Mount Tangkuban Parahu area did not reach the Bandung Plain. This study clearly demonstrates the usefulness of these environmental tracers and hydraulic head measurement in identification of the groundwater flow system of a certain area.

 Articles related

Yuyun Yuniardi,Hendarmawan Hendarmawan,Abdurrokhim Abdurrokhim,Vijaya Isnaniawardhani,Febriwan Mohammad,Muhammad Kurniawan Alfadli,Panji Ridwan    

Airtanah sangat diperlukan dan meningkatnya jumlah penduduk akan menyebabkan pengurangan cadangan airtanah yang tersedia. Gunung Tangkubanparahu merupakan daerah endapan vulkanik yang memiliki potensi sistem akuifer airtanah yang baik. Tujuan penelitian ... see more


Thomas Triadi Putranto,Daniel Setiawan    

Wilayah Cekungan Airtanah (CAT) Pati-Rembang berada di daerah Kabupaten Pati, Jepara, dan Rembang, Provinsi Jawa Tengah. Pertumbuhan jumlah penduduk akan menyebabkan peningkatan kebutuhan air bersih. Salah satu sumber air bersih berasal dari airtanah dar... see more


Taat Setiawan,Soeharti Isnaini,Novi M. A. Asghaf,Idham Effendi    

Penelitian ini dilakukan dengan pengukuran sifat fisika dan kimia air di lapangan berupa suhu, daya hantar listrik, pH, dan ion HCO3-, serta analisis hidrokimia di laboratorium terhadap contoh air dari sumur bor, mata air, dan sungai bawah tanah. Interpr... see more


Arief Nur Muchamad,Boy Yoseph CSS Syah Alam,Euis Tintin Yuningsih    

This paper describes the groundwater quality assessment conducted in Katak lowland area, in Banyuwangi District, East Java. The quality of water salinity had been identified during field observation. In order to identify the origin of saline groundwater,... see more


Wulan Seizarwati,Heni Rengganis,Muhshonati Syahidah    

Before rapid urban development happened in DKI Jakarta during the 1960s, most of the area was still covered by primary forest and swamp, so that recharge potential is still very high. Landuse change causes disruption of recharge capacity to replenish gro... see more