Removal of temperature drift of zero of piezoelectric accelerometer

SUMMARY

The object of research is the dependence of the results of measuring vibrational acceleration by a piezoelectric accelerometer on the influence of ambient temperature. The indicated dependence is a change in the constant level in the measured signal. This is caused by the generation of an additional charge by the piezoelectric element of the accelerometer in the absence of impact on it from the side of the measurement object. The specified additional charge is generated under the influence of changes in the temperature of the medium on the structure of the sensitive element. This leads to an increase in the error of the measurement result. The larger the range of fluctuations in temperature and the rate of change in the temperature of the medium over time, the greater the effect on the measurement results. Since changes in temperature over time compared with the frequency of measured vibrations are much slower processes and their influence on the measurement result is constant in the entire dynamic range of the accelerometer, they represent an additive component of the error in these measurements.During the study, in order to prevent the temperature influence of the medium on the measurement process, methods for its elimination are considered and solutions for improving the piezoelectric accelerometer by introducing a compensation element in its design are proposed. In order to reduce the influence of temperature fluctuations of the medium on the measurement results, a controlled piezoelectric element operating on the inverse piezoelectric effect along the polarization axis is used as a compensation element. The resulting solution is easily implemented from a technical point of view, since the compensation element and the sensitive element are made of the same material and have the same coefficient of thermal expansion. The compensation element is controlled by an automatic regulation system that works on the principle of deviation regulation.Thanks to the method proposed in this work, it is possible to increase the accuracy of measurements performed using piezoelectric accelerometers and to expand their scope in relation to the requirements for the ambient temperature.

 Articles related

Aleksey Zagorulko,Andreii Zahorulko,Bogdan Liashenko,Iryna Gordienko    

The object of research is the temperature field of the working surface of the rotor-film apparatus (RFA) when heated by a nichrome spiral with a different coolant layer or using a flexible film resistive radiating type electric heater (FFREHRT). Since th... see more


Olena Bilyk,Oksana Kochubei-Lytvynenko,Yulia Bondarenko,Olha Chernyushok    

An important problem of bakery is the prevention of the main causes of spoilage of bread, namely the development of microorganisms, which, under favorable conditions, become activated and lead to complete unsuitability of the product for consumption. The... see more


Mykola Gordiuk,Mykola Semynoh,Oleksandr Holodnov,Igor Tkachuk,Boris Ivanov    

The object of research is the residual resource of the structures of buildings and structures after various influences. The residual resource is the total operating time of the object from the moment of monitoring its technical condition to the transitio... see more


Pablo Xavier Jumbo Pacheco, Diego Alejandro Nieto Monteros    

RESUMENEl cianuro es el compuesto químico empleado por excelencia para la lixiviación de oro en la industria minera. Sin embargo, es altamente tóxico para los organismos que se desarrollan alrededor de las industrias mineras, y para el medio ambiente. Co... see more

Revista: MASKANA

Khaled Muftah Elsherif, Aisha Khalifa Ali, Abdulfattah Mohammed Alkherraz, Abdelmeneim El-Dali    

The aim of the present study is to investigate the efficiency of palm leaves activated carbon on the removal of lead (Pb), zinc (Zn), copper (Cu), and cadmium (Cd) from the aqueous solution. The effect of various process parameters such as pH (2 – 10), i... see more