ARTICLE
TITLE

Assessment of Physiological Equivalent Temperature (PET) in Transitional Spaces of a High-Rise Building

SUMMARY

One passive approach that can significantly reduce energy usage in high-rise buildings is through the creation of non-air conditioned spaces such as transitional spaces. Optimizing passive design would reduce wastage associated with the building’s energy consumption. The study measures the thermal comfort of three types of transitional spaces (sky court, balcony, and rooftop) in a high-rise office building. Based on the assessment of Physiological Equivalent Temperature (PET), the outcome showed significant differences in PET in all locations in both wet and dry season. The effectiveness of such area can be improved with the contributions of landscape, maximizing natural ventilation and day lighting where possible.Keywords: Thermal comfort; transitional spaces; high-rise; Physiological Equivalent TemperatureeISSN 2398-4295 © 2018. The Authors. Published for AMER ABRA cE-Bs by e-International Publishing House, Ltd., UK. This is an open-access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/). Peer–review under responsibility of AMER (Association of Malaysian Environment-Behaviour Researchers), ABRA (Association of Behavioural Researchers on Asians) and cE-Bs (Centre for Environment-Behaviour Studies), Faculty of Architecture, Planning & Surveying, Universiti Teknologi MARA, Malaysia. 

 Articles related

Gonzalo Gil-Moreno-De-Mora,Joan Palmi Guerrero,Joan Antoni Prat-Subirana    

Los deportistas que participan en el Rally-raid Dakar deben mostrar su competencia para dar respuesta a un esfuerzo de larga duración en el que intervienen factores limitantes de carácter psicológico y fisiológico por la fatiga acumulada durante el esfue... see more