ARTICLE
TITLE

The Severity of Positional Mitral Regurgitation during Off-Pump Coronary Artery Bypass Grafting

SUMMARY

Background. The aims of this study were to elucidate the incidence of mitral regurgitation during off-pump coronary artery bypass (OPCAB) surgery to evaluate the relationship of the changes with ventricular function and possible mitral valve regurgitation caused by positioning.Methods. Included in the study were 60 consecutive patients who underwent CAB grafting on the beating heart. We monitored several hemodynamic variables (systolic arterial pressure, mean arterial pressure, right atrial pressure, pulmonary capillary wedge pressure, and heart rate) at baseline and after each anastomosis and used transesophageal echocardiography (TEE) routinely after sternotomy, during each anastomosis, and after completion of the operation. Valvular functions, ejection fraction, and wall motion systolic index were recorded during each TEE evaluation.Results. All of the patients underwent complete revascularization. We performed 132 consecutive OPCAB anastomoses in 60 patients (60 left anterior descending artery [LAD], 20 right coronary artery [RCA], 45 left circumflex coronary artery [LCX], and 7 diagonal artery grafts). During LCX anastomosis, 38 (84.4%) of 45 patients developed moderate mitral regurgitation. The wall motion score index (WMSI) significantly increased during CX grafting, as was demonstrated by higher WMSI values than for the RCA, diagonal, and LAD grafts. The ejection fraction was decreased significantly during CX and RCA anastomoses compared with baseline levels. The hemodynamic changes were in accord with these findings. The greatest hemodynamic compromise was seen during CX anastomosis.Conclusion. Positional mitral regurgitation occurs frequently and is a major contributor to hemodynamic instability during posterior- and lateral-wall revascularization during the OPCAB procedure.

 Articles related

Mustafa Güden, Ilhan Sanisoglu, Ertan Sagbas, Mehmet U. Ergenoglu, Ugur Ozbek, Belhhan Akpinar    

Background: The aim of this study was to compare intraoperative coronary graft flows performed on pump and off pump and to evaluate the effects of hemodilution on coronary graft flows in off-pump coronary artery bypass grafting (CABG) patients by using t... see more


Hirokuni Arai, Akira Kozakai, Susumu Manabe, Satoru Kawaguchi, Masato Shimizu, Koso Egi, Noriyuki Tabuchi, Hiroyuki Tanaka, Makoto Sunamori    

Background: Coronary shunts are widely used to prevent myocardial ischemia during off-pump coronary artery bypass graft (OPCAB) procedures. Although clinical effectiveness has been reported, actual perfusion flow has not been well assessed. The purpose o... see more


Satoru Nishida, Yujiro Kikuchi, Go Watanabe, Yoshiko Shintani, Shigeki Ito, Shigeki Tabata, Kenji Kawachi    

The PAS-Port system allows for the rapid deployment of a clampless proximal anastomosis between a saphenous vein graft and the aorta. We have developed a simple technique of establishing traction of the ascending aorta with the Starfish heart positioner ... see more


A. Kurita, H. Shintani    

Background: Although off-pump coronary artery bypass grafting (CABG) is now used worldwide for coronary revascularization, the pre- and intraoperative risk factors for myocardial injury associated with the surgical procedure remain to be elucidated. We p... see more


Juha K. Koskenkari, Jussi Rimpiläinen, Hanna Öhman, Heljä-Marja Surcel, Vilho Vainionpää, Fausto Biancari, Tero Ala-Kokko, Tatu Juvonen    

Objective. Cardiopulmonary bypass-induced systemic inflammatory reaction involving the expression of neutrophil surface adhesion molecules is the main mechanism leading to myocardial ischemia-reperfusion injury as well as multiorgan dysfunction. Patients... see more