ARTICLE
TITLE

The Potential Value of Hybrid Positron Emission Tomography/Dual-Source Computed Tomography Imaging in Coronary Bypass Surgery

SUMMARY

Background: We evaluated how comprehensive assessment of coronary artery lesions and their hemodynamic relevance by means of hybrid positron emission tomography (PET) and computed tomography (CT) imaging would affect decision-making in coronary artery bypass surgery (CABG), compared with using invasive coronary angiography (ICA) alone.Methods: After undergoing ICA, 27 patients (21 men and 6 women; mean SD age, 66 ± 10 years) planned for cardiac surgery were scheduled for myocardial perfusion stress/rest evaluation with [13N]ammonia PET and CT coronary angiography. Only ICA was available to the surgeon. Postoperatively, the performed CABG was compared with the hypothetical strategy based on hybrid PET/CT findings (regional coronary flow reserve [CFR], myocardial perfusion defects). Procedures included CABG (n = 18) alone, CABG combined with valve replacement (n = 6), and CABG combined with isolated valve replacement (n = 3). A total of 56 bypass grafts (28 venous and 28 arterial) and 66 distal anastomoses were placed.Results: CT evaluation showed 93% concordance (66/71) with ICA regarding significant stenoses, with sensitivity, specificity, positive predictive value, and negative predictive value of 93.1%, 98.7%, 94.4%, and 98.4%, respectively. In the PET scan, 16 patients had 1 ischemic region, and 12 patients had 1 scar region, including 5 patients who presented with mixed conditions (scar and ischemia). One patient had a completely normal myocardium. Compared with the performed surgery, PET/CT fusion evaluation showed that of the performed anastomoses, 48% had documented ischemia (with a CFR <2 in 86%), 38% were nonischemic (although a CFR value <2 was found in 78%), and 14% had scar tissue (fixed perfusion defect).Conclusions: Although <50% of bypasses were placed to areas with myocardial ischemia, the CFR was low in the majority of nonischemic regions, a finding that may have important prognostic relevance. PET/CT fusion imaging could potentially influence planning for CABG and provide incremental prognostic information.

 Articles related

Mario Stalder, Erich Gygax, Franz F Immer, Lars Englberger, Hendrik Tevaearai, Thierry P Carrel    

Objective. The standard heart-lung machine is a major trigger of systemic inflammatory response and the morbidity attributed to conventional extracorporeal circulation (CECC) is still significant. Reduction of blood-artificial surface contact and reducti... see more


Hrvoje Gašparovi?, Branko Maloj?i?, Marko Borojevi?, Jakov Vojkovi?, Rajka Gabelica, Davor Mili?i?, Bojan Bio?ina    

Background: Neurologic deficits are perhaps the most feared form of adverse outcome following cardiac surgery. Aortic trauma generates emboli and hence harbors the potential for neurocognitive injury. The single aortic clamp strategy of coronary artery b... see more


Michael S. Firstenberg, Cornelius M. Dyke, Dominick J. Angiolillo, Chandrashekhar Ramaiah, Matthew Price, Miroslav Brtko, Ian Welsby, Harish Chandna, David R. Holmes, Michele Voeltz, Pradyumna Tummala, Martin Hutyra, Steven V. Manoukian, Jayne Prats, Meredith Todd, Tiepu Liu, Nicholas Chronos, Markus Dietrich, Gilles Montalescot, Louis A. Cannon, Eric J. Topo    

Objective: Oral P2Y12 platelet receptor inhibitors are a cornerstone of reducing complications in patients with acute coronary syndromes or coronary stents. Guidelines advocate discontinuing treatment with P2Y12 platelet receptor inhibitors before surger... see more


Nan Cheng, Liuquan Cheng, Rong Wang, Lin Zhang, Changqing Gao    

Objective: The aim of this study was to quantify left ventricular torsion by newly applied cardiovascular magnetic resonance feature tracking (CMR-FT), and to evaluate the clinical value of the ventricular torsion as a sensitive indicator of cardiac func... see more


Windhi Dwijanarko,Erika Maharani,Dyah Wulan Anggrahini    

Background: In STEMI patients, the duration of action potential dispersion occurs between normal and ischemic tissue due to the lengthening of the refractory period, causing transmural dispersion of repolarization, which could be detected with Tp-Te inte... see more