ARTICLE
TITLE

Bond strength of composite resin containing biomaterial S-PRG to eroded dentin

SUMMARY

Aim: To evaluate the bond strength of composite resin containing or not biomaterial (S-PRG) to sound/eroded dentine. Methods: Occlusal dentin of 30 human molars (n=15) had half of its surface kept uneroded, while on the other half an erosive lesion was produced by cycling in citric acid (pH 2.3) and supersaturated solution (pH 7.0). On both eroded (ED) and non-eroded (SD) substrates, two restorative systems (containing or not S-PRG) were tested. Composite resin cylinders were built and, after storage in water (24h), were submitted to bond strength test. The analysis of the fracture pattern was performed under an optical microscope (40x). The obtained values of bond strength (MPa) were submitted to ANOVA (two factors) and Tukey multiple comparisons tests (p<0.05). Results: According to the results, there was difference between substrates (<0.001) and restorative materials (p=0.002) evaluated. For the microtensile bond strength, the values obtained were: SDNB (47.6±12.2 MPa), SDWB (34.1±15.8 MPa), EDNB (31.1±8.3 MPa) and EDWB (15.5±13.6 MPa), revealing a statistically significant difference in the evaluated substrates and restorative materials. Conclusion: Bond strength of eroded substrate is inferior to the sound substrate and the restorative system containing S-PRG biomaterial influences negatively the results of bonding to sound/eroded dentin.

 Articles related

Myrna Nurlatifah Zakaria,Moch. Richata Fadil,Milly Armilia    

Resin based luting cement application generally requires pre-treatment procedure such as etching and adhesive application prior to cementation. This multi-step application technique might compromise bonding alternative effectiveness and is time consuming... see more


Erna Kurnikasari,Muslich Mahmud,Hasna Dziab    

Denture consists of acrylic artificial teeth and acrylic prothesis base bond chemically with a bond strength of 315 kgF/cm2. Most of the commercial acrylic artificial teeth do not specify their specifications and all of those acrylic artificial teeth do ... see more


Masoud Fallahinejad Ghajari, Mahsa Sheikholeslamian, Amir Ghasemi, Leila Simaei    

Objectives: This study aimed to determine the microtensile bond strength (µTBS) of a bulk-fill composite to permanent and primary coronal dentin using a universal adhesive in self-etch and total-etch modes.Materials and Methods: This in-vitro study was p... see more


Shabnam Milani, Bahman Seraj, Zahra Khoshlafz, Niusha Abazarian    

Objectives: Achieving durable restorations with adequate strength in severely damaged primary anterior teeth in children is a priority. The aim of this study was to investigate the effect of dentin pretreatment with chlorhexidine on push-out bond strengt... see more


Pinandi Sri Pudyani,Setiarini Widiarsanti    

Background: Fixed orthodontic appliances with ceramic brackets are used frequently to fulfill the aesthetic demand of patient through orthodontic treatment. Ceramic brackets have some weaknesses such as bond strength and enamel surface damage. In high bo... see more