Home  /  Atom Indonesia  /  Vol: OL49 Núm: NO1 Par: 0 (2023)  /  Article
ARTICLE
TITLE

Dose Evaluation of Head and Neck Cancer IMRT Treatment Planning Based on Gamma Index Analysis of Varian Halcyon 2.0 Linac

SUMMARY

Varian Halcyon 2.0 linear accelerator was launched and became available for clinical use in 2018. Therefore, it is necessary to evaluate the accuracy of exit fluence of the Halcyon 2.0 for quality assurance (QA) of head and neck cancer treatment planning, pretreatment, and treatment. The accuracy of the exit fluence for twenty treatment plannings has been evaluated by conducting gamma analysis for QA pretreatment and treatment in each field and composite field by using criteria for gamma index 3 %/3 mm and 2 %/2 mm. The QA pretreatment results are in the average value for each criterion for each field and composite fields on actual gantry angle and null gantry angle with gamma passing rate (GPR) of over 99 % (range 99.78 %-99.95 %) The total treatments consisted of 2717 fractions. The analysis results of GPR for fields were 99.32 % and 97.74 % for gamma indexes of 3 %/3 mm and 2 %/2 mm, respectively. In addition, the analysis results of GPR for composites were 95.46 % and 81.38 % for gamma indexes of 3 %/3 mm and 2 %/2 mm, respectively. Based on this result, the average GPRs of QA pretreatment are ˜ 99 % of the total pixels. This means the prediction dose of Varian Halcyon 2.0 is accurate. The average GPRs of treatment is nearly > 90 %, showing that Varian Halcyon 2.0 is effective for creating treatment plans for complex cases.

 Articles related

H.M. Qadr    

An investigation into the effects of proton beam exposure on high- and low-copper structural materials for nuclear reactors has been carried out. The aim of this work was to investigate the impact of proton energy irradiation on the damage of the materia... see more

Revista: Atom Indonesia

D. Ramadhani,S. Purnami,S. Nurhayati,M. Lubis,D. Tetriana,W. Mailana,K. D. Purwanti,E. Pudjadi,I. Kashiwakura,R. Okazaki,M. Syaifudin    

People living in high background radiation area (HBRA) possibly developed the radioadaptive response (RAR) phenomena. Mamuju area in West Sulawesi Indonesia also known as the HBRA in Indonesia due to high natural uranium contents. It is possible that RAR... see more

Revista: Atom Indonesia

Fitrotun Aliyah, Azhar Abdul Rahman, Yasmin Md Radzi, Imam Kambali    

Neutron encounters difficulties in shielding protection. Thus, many researchers have performed simulation and experimental research on neutron shielding materials. The characteristic of materials is highly dependent on neutron energy. The evaluation of n... see more


Daniele Pistone,Lucrezia Auditore,Antonio S. Italiano,Giuseppe Mandaglio,Fabio Minutoli,Sergio Baldari,Ernesto Amato    

Monte Carlo simulation of radiation transport is the most accurate and patient-specific technique available for internal dosimetry in nuclear medicine. Taking morphological and functional information from CT and PET 3D scans, it is possible to perform MC... see more


Asif Nuruddin Shaikh, Vishal Yadav, Prakash Jadhav (Author)    

The objective of controlled drug delivery systems is to reduce the frequency of the dosing and to increase the effectiveness of the drug. In oral controlled drug delivery system, multiple unit dosage forms (MUDF’s), like pellets, granules and mini tablet... see more