ARTICLE
TITLE

Influence of Bioactive, Resin and Glass Ionomer luting cements on the fracture loads of dentin bonded ceramic crownsFailure loads of Ceramic crowns bonded with Bioactive cement

SUMMARY

Objective: To investigate the failure loads of dentin bonded all-ceramic crowns when luted with Bioactive, resin and glass ionomer cements (GIC) in an in-vitro setting.Methods: This study was conducted at King Saud University, Saudi Arabia, from Nov.2018 to March 2019. In this study, 60 premolar teeth were prepared for dentin-bonded ceramic crowns. Lithium disilicate ceramic crowns fabricated using CAD-CAM technique were cemented to teeth using Bioactive (ACITVA), Resin (Nexus 3 Gen) and GIC (Ketac Cem- Maxicap). Half of the bonded specimens in each group were thermocycled (50000 cycles), however the remaining half were not aged (n=10). Fracture loads of bonded crowns were assessed by exposing them to static axial occlusal loads (1mm/min) using a round ended metal probe in a Universal testing machine. Means and standard deviations among the study groups were compared with ANOVA and Tukey-Kramer multiple comparisons test.Results: Highest failure loads were observed in resin group without ageing (thermocycling) (689.13±89.41 N), however, the lowest loads were observed in GIC specimens with ageing (243.16±49.03 N). Among non-aged samples, failure loads for Bioactive (480.30±47.26 N) group were less than Resin (689.13±89.41 N) samples but higher than GIC (307.51±45.29 N) specimens respectively. Among the aged specimens, Bioactive (404.42±60.43 N) showed significantly higher failure loads than GIC (243.16±49.03 N), however lower failure loads than Resin (582.33±95.95 N) samples.Conclusions: Dentin boned crowns with resin cementation showed higher failure loads than Bioactive and GIC luted crowns. Crowns luted with Bioactive cement showed acceptable failure loads for use as restoration on anterior teeth.doi: https://doi.org/10.12669/pjms.36.3.1946How to cite this:Vohra F, Altwaim M, Alshuwaier AS, Al-Deeb M, Alfawaz Y, Alrabiah M, et al. Influence of Bioactive, Resin and Glass Ionomer luting cements on the fracture loads of dentin bonded ceramic crowns. Pak J Med Sci. 2020;36(3):416-421.  doi: https://doi.org/10.12669/pjms.36.3.1946This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

 Articles related

Sri Rahajoe Asj'ari Sri Rahajoe Asj'ari    

Levels of blood Hb, glucose and lactic acid were estimated two times to 49 athletes of badminton and tennis (13-27 years old). The estimations were done before and after physical performance test. The loads of physical performance test for the subjects w... see more


Deepashini Harithasan,Devinder Kaur Ajit Singh,Baharudin Omar    

Plantar pressure, force and contact area information may provideinsights regarding stresses imparted to the foot when performing functional tasks. There is limited information regarding plantar pressure, force and contact area when carrying incremental l... see more


Ki-Hyung Yu, Seong-Hoon Yoon, Hae-Kwon Jung, Kee Han Kim and Kyoo-Dong Song    

Under-floor air distribution (UFAD) systems are occupied-area-based air conditioning systems that generally offer advantages over ceiling-based air distribution (CBAD) systems in terms of energy efficiency and thermal comfort; accordingly, UFAD systems h... see more

Revista: Energies

Peter Zuidewind,Mark Cotton,Shaun Barnabas,Anita Janse van Rensburg,Gert van Zyl,Carli Gordijn    

AbstractPaediatric HIV spontaneous controllers (HSCs) are a unique and understudied population with potential to inform alternative treatment options for patients living with HIV. As HSCs are so rare and often not recognised prior to antiretroviral treat... see more


Êmyle Martins Lima,Herman Henrique Silva Santana,Alena Peixoto Medrado,Ana Maria Blanco Martinez,Abrahão Fontes Baptista    

Peripheral nerve lesions may be associated with abnormal scarring that lead to regenerative failure and dysfunction. Neurodynamic mobilization (NM) imposes controlled mechanical loads on the peripheral nerve and may influence inflammation and collagen de... see more