Flow-synchronized nasal intermittent positive pressure ventilation in the preterm infant: development of a project

SUMMARY

This manuscript describes the experience of our team in developing a flow-triggered nasal respiratory support for the neonate and its related clinical applications. Although mechanical ventilation (MV) via an endotracheal tube has undoubtedly led to improvement in neonatal survival in the last 40 years, the prolonged use of this technique may predispose the infant to the development of many possible complications, first of all, bronchopulmonary dysplasia (BPD). Avoiding mechanical ventilation is thought to be a critical goal, and different modes of non invasive respiratory support may reduce the intubation rate: nasal continuous positive airway pressure (NCPAP), nasal intermittent positive pressure ventilation (NIPPV) and its more advantageous form, synchronized nasal intermittent positive pressure ventilation (SNIPPV). SNIPPV was initially performed by a capsule placed on the baby’s abdomen. To overcome the disadvantages of the abdominal capsule, our team decided to create a flow-sensor that could be interposed between the nasal prongs and the Y piece. Firstly we developed a hot-wire flow-sensor to trigger the ventilator and we showed that flow-SNIPPV can support the inspiratory effort in the post-extubation period more effectively than NCPAP. But, although accurate, the proper functioning of the hot-wire flow-sensor was easily compromised by secretions or moisture, and therefore we started to use as flow-sensor a simpler differential pressure transducer. In a following trial using the new device, we were able to demonstrate that flow-SNIPPV was more effective than conventional NCPAP in decreasing extubation failure in preterm infants who had been ventilated for respiratory distress syndrome (RDS). More recently we used flow-SNIPPV as the primary mode of ventilation, after surfactant replacement, reducing MV need and favorably affecting short-term morbidities of treated premature infants. We also successfully applied SNIPPV to treat apnea of prematurity (AOP). Finally, we developed a new shaped flow-sensor, which is smaller and lighter of the previous one and its reliability was tested using a simulated neonatal model. 

 Articles related

--- Various Authors    

 LECT 1. RESUSCITATION OF EXTREMELY PREMATURE INFANTS: HOW TO IMPROVE EVEN FURTHER • J.M. PerlmanLECT 2. MAINTAINING NORMAL TEMPERATURE IN THE NEWLY BORN: NOT A TRIVIAL GAME • J. WyllieLECT 3. PRESENT AND FUTURE OF SURFACTANT AD­MINISTRATION IN PRET... see more


--- Various Authors    

ABS 1. AN OPEN LABEL, DOSE-ESCALATION STUDY OF LUCINACTANT FOR INHALATION DELIVERED VIA NASAL CONTINUOUS POSITIVE AIRWAY PRESSURE (nCPAP) FOR TREATING RESPIRATORY DISTRESS SYNDROME (RDS) IN PRETERM NEONATES • J. Mazela, N.N. Finer, S.G. Simonson, PM. Sho... see more


--- Various Authors    

ABS 1. PROPHYLACTIC VERSUS SELECTIVE USE OF SURFACTANT IN PRETERM INFANTS BORN AT LESS THAN 30 WEEKS GESTATION OR WITH BIRTH WEIGHT LESS THAN OR EQUAL TO 1,250 GRAMS IN KOREA: KOREAN NEONATAL NETWORK • E.H. Lee, T. Sung, E. Kim, Y. Kim, J. Kim, N.R. Lee,... see more


--- Various Authors    

LECT 1. COMPLEMENTARY FEEDING IN PRETERM IN­FANTS: MYTHS AND FACTS • A. AcetiLECT 2. NEONATAL HYDRONEPHROSIS • R. AgostinianiLECT 3. WHEN A NEWBORN DIES IN NICU • M. Susi, S. Dosso, A. Anselmi, A. Bertolini, P. BibanLECT 4. RED REFLEX TESTING IMPLEMENTAT... see more