Home  /  Atom Indonesia  /  Vol: 44 Núm: 3 Par: 0 (2018)  /  Article
ARTICLE
TITLE

An Experimental Analysis on Nusselt Number of Natural Circulation Flow in Transient Condition Based on the Height Differences between Heater and Cooler

SUMMARY

A better understanding on the phenomenon of natural circulation flow for cooling systems is necessary prior to improving the safety of nuclear power plant, not only in normal operation but also in accident conditions. One way to understand this phenomenon is by analyzing the Nusselt number in various geometrical dimensions through experimentation. The purpose of this study is to understand natural circulation phenomenon in transient condition by varying height differences between heater and cooler. To achieve this purpose, an experiment apparatus called NC-Queen was developed and arranged to enable three variations of height differences between heater and cooler, i.e., 1.4 m, 1.0 m, and 0.3 m. It is made of a stainless steel tube with a diameter of 1 inch, arranged in rectangular shape 6.4 m in length, and uses water as coolant. The initial temperature of the heater was set at 90 °C. The Nusselt number was obtained by calculating the flow rate as a function of transient temperature. The results confirm that height differences affect thermal properties and flow region based kinetics characteristics of water. In initial condition, decreasing height difference from 1.4 m to 1.0 m resulted in flow rate reduction of 16.7 %, while decreasing height difference from 1.4 m to 0.3 m resulted in a 39.1 % flow rate reduction. In final condition, the flow rate reductions were 75 % and 82.6 %, respectively. Meanwhile, in initial condition, the Nusselt number for height difference reduction from 1.4 m to 1.0 m and from 1.4 m to 0.3 m decreased by 30.5 % and 74.6 %, respectively, while for final condition, the Nusselt number decreased by 11.9 % and 67.4 %, respectively. The new constants in relationship between Nusselt number and the height difference are a = 20.06 and   b = 0.56. The dominance of turbulent flow provides a good safety margin with indications of the large amount of heat released.

 Articles related

C Poette,P Reynier    

The present contribution focuses on the evaluation of non-intrusive 3D mapping experimental methods for the investigation of multiphase flows during tank sloshing. This problem is a key issue for launchers and satellites since the feeding in propellants ... see more


E Haque,P Hampson    

A 3D thermal transient analysis of a gap profiling technique which utilises phase change material (plasticine) is conducted in ANSYS. Phase change is modelled by assigning enthalpy of fusion over a wide temperature range based on Differential Scanning Ca... see more


D Pan,L Xia,M Chan,S Deng    

This paper reports an experimental and numerical study on a sleeping thermal manikin in a room equipped with a mixed ventilation system. In the experimental work, heat loss from the sleeping thermal manikin was measured under different conditions. The su... see more


Tagor Malem Sembiring,Pungky Ayu Artiani    

The 10 MW HTR Indonesian Experimental Power Reactor (RDE reactor) is designed identical with the HTR-10 in China, conceptually.  However, the review results showed that the spent fuel cask model which is used between two reactors is fully different,... see more

Revista: Tri Dasa Mega

P. R. Selskyy, A. T. Televiak, T. O. Veresiuk, B. P. Selskyy    

Background. The study proposes a method for optimizing the prediction of the development of ischemic disorders by experimental acute ischemia-reperfusion based on combined changes in biochemical parameters. The approach is based on the calculation of cor... see more