ARTICLE
TITLE

Condition Monitoring of Centrifugal Pumps Based on Pressure Measurements

SUMMARY

The purpose of the present study is the investigation of condition of centrifugal pumps via pressure signals. Instead of vibration measurement on the housings that is widely used in industry, our method is based on pressure signal measurement on the pressure side of the pump. Fourier transforming such a signal can get us to make conclusions about the behavior of the pump. By changing the operating point along a characteristic curve, we can create waterfall diagrams that provide useful information about the pump at constant rotational speed. For example, it is possible to differentiate the mechanical and the hydrodynamical effects predicting the occurrence of many constructional failures (such as unbalance, angular misalignment, bearing misalignment, motor instability, etc.); thus, preventing heavy damage of the equipment.

 Articles related

Fahad Ghalib Abdulkadhim, Zhang Yi, Mudassar Khalid    

Smart mobile pharmacy has become a necessary requirement in improving the quality of healthy life in the last five years. Determining the type of medication and calculating the dose for each patient according to the patient's condition, monitoring the pa... see more


LUCAS BARRETO, MARCELA MACHADO, JULIANA CARDOSO SANTOS, BRAION BARBOSA DE MOURA, LEILA KHALIJ    

DAMAGE DETECTION IN STRUCTURES IS ESSENTIAL FOR MONITORING PARAMETERS THAT CAN AFFECT THE RELIABILITY OF THE ENGINEERING SYSTEM. THIS WORK EVALUATES THE EFFICIENCY OF RMSD, MAPD, COV, AND CCD DAMAGE INDICES (DIS) COMMONLY USED WITH TEMPORAL WAVE SIGNALS.... see more


Dhodit Rengga Tisna, M. Udin Harun Al Rasyid, Sritrusta Sukaridhoto    

The performance condition of an athlete must always be maintained, one way to maintain that performance is by training. Each individual has different abilities and physiological responses in receiving the portion of the exercise. Physical exercise that e... see more


Mardawia Mabe Parenreng,Fajria Nur,Asriyadi Asriyadi    

Each laboratory has a person in charge (technician) that has a duty of serving the laboratory in term of operational and maintenance. The main task of a technician is to record and monitor the condition and completeness of laboratory equipment in the lab... see more


Muhammad Zikri,Rizaldy Khair    

Air pollution is a condition with air quality becomes damaged and contaminated by substances. Lack of information on air pollution in Medan cause people not to be aware of the increase of air pollution. In this study an Arduino-based air pollution monito... see more