Fire Resistance of Axially Loaded Slender Concrete Filled Steel Tubular Columns – Development of a Three-Dimensional Numerical Model and Comparison with Eurocode 4

SUMMARY

In recent years, concrete filled tubular (CFT) columns have become popular among designers and structural engineers, due to a series of highly appreciated advantages: high load-bearing capacity, high seismic resistance, attractive appearance, reduced column footing, fast construction technology and high fire resistance without external protection. In a fire, the degradation of the material properties will cause CFT columns to become highly nonlinear and inelastic, which makes it quite difficult to predict their failure. In fact, it is still not possible for analytical methods to predict with enough accuracy the behaviour of columns of this kind when exposed to fire. Numerical models are therefore widely sought. Many numerical simulations have been carried out worldwide, without obtaining satisfactory results. This work proposes a three-dimensional numerical model for studying the actual fire behaviour of columns of this kind. This model was validated by comparing the simulation results with fire resistance tests carried out by other researchers, as well as with the predictions of the Eurocode 4 simplified calculation model. 

 Articles related

Bhavana B,Sindhu D    

The purpose of this paper is to investigate the behavior of the composite structure under fire. The main objective of fire structural analysis is to predict the effect of fire on buildings. The resistance and the structural performance under heating caus... see more


Olena Chulieieva,Volodymyr Zolotaryov    

The level of electrophysical properties of fireproof polymer compositions, depending on the influence of ingredients, has not been sufficiently studied. This is especially true of the effect of the modifier on the properties of the insulation and sheath ... see more


Olena Chulieieva    

The object of research is the electrophysical properties of fireproof composite materials of ethylene with vinyl acetate, which include filler-flame retardants and modifiers. One of the biggest problems is the change in the electrophysical properties of ... see more


Helmy Purwanto, Mohammad Tauviqirrahman, Sugiarto Sugiarto, Muhammad Dzulfikar    

Ballistic resistance is affected by the projectile and armor material used. The character and behavior of the projectile affects its ability to damage and penetrate armor. The velocity, mass and shape of the projectile are the main factors in determining... see more


Muhammad Akhis Thoyfurrohman,Bagas Indra Cahyo,Erika Yulianti,Nuroji Nuroji,Yulita Arni Priastiwi    

Abstrak Beton yang mengalami kebakaran pada suhu 400°C akan mengalami degradasi kekuatan hingga kuat tekan sisa 58,40% Hal ini akan mempengaruhi kualitas/kekuatan struktur beton tersebut dan akan menyebabkan beton menjadi getas, dan memungkinkan str... see more