ARTICLE
TITLE

Focal Length Lens Effect at Non-Metric Camera for Three-Dimensional Models Result

SUMMARY

Selections of non-metric cameras can be calculated properly starting from choosing the right camera sensor size and lens focal length to get better results. Differences in the choice of focal length in shooting can affect the resulting photo. The resulting photo may differ from how much of the object is captured and may suffer distortion due to different selections of the focal length. The purpose of this study is to show the magnitude of the effect of focal length variation in making a three-dimensional model based on the comparison of the results of the three-dimensional model visualization, the comparison of the results of geometric accuracy based on the independent checkpoint coordinate data, and the comparison of the distance results between retro targets. The results of this study indicate that a focal length of 70 mm has better results with the formation of the object completely resembling its original object compared to a focal length of 28 mm which is not good at forming a safety pillar on the bridge. The results of the RMSE value based on ICP coordinate data at a focal length of 70 mm are better with a value of 0.083 m compared to a focal length of 28 mm with a large value of 0.123 m. The results of the RMSE value based on the distance between retro targets at a focal length of 70 mm are better with a value of 0.003 m compared to a focal length of 28 mm with a large value of 0.004 m.

 Articles related

Fabrizio Bernardi,Maria Grazia Ciaccio,Barbara Palombo,Graziano Ferrari    

In this paper we present a new study on the High Tiber Valley earthquake occurred on April 26, 1917. Using the digitized data from mechanical seismograph records, we computed the source parameters like focal mechanism and moment magnitude from moment ten... see more


C. Benetatos,Z. Roumelioti,A. Kiratzi,N. Melis    

Teleseismic body wave modelling, time domain moment tensor inversion of regional waveforms and spectral analysis of the far-field P-wave pulses are used to derive the source parameters of the July 26, 2001 Skyros earthquake (M 6.5). Its epicentre is loca... see more


K. M. Abou Elenean,H. M. Hussein,A. S. Abu El-Ata,E. M. Ibrahim    

On 12 October 1992 a significant earthquake (MB = 5.8) occurred southwest of Cairo in the vicinity of the Dahshour region. For the mainshock, an average moment release M 0 = 9.70E17 n-m; a fault length = 13.8 km; an average displacement = 0.22 m; a stres... see more


A. Kiratzi,E. Louvari    

Body waveform modelling and far-field displacement spectral analyses were used to study the source parameters of five of the largest earthquakes of the (Izmit-Bolu) Turkey 1999 sequence. The derived source parameters for the August 17, 1999 M W 7.4 event... see more


Hadeel K. Nasif,Baida M. Ahmed,Kadhim A. Aadim    

A spectroscope presents the optical emission spectroscopy (OES) technique on laser-produced copper and silver plasmas. The optical emission spectrum technique was used to analyzes the spectrum arising from the Cu, Ag Laser Nd: YAG plasmas with a waveleng... see more