ARTICLE
TITLE

Location Optimization of a Hydraulic Turbine for Koudiet Acerdoune Water Treatment Plants

SUMMARY

This study aims to recover the residual energy of the water in the water treatment plant using turbines instead of wasting energy in the dissipator as it is currently done by means of load- breaker valves. Analysis of the technical efficiency of the project and an assessment of the hydroelectric potential available were carried out and different options for the installation of turbines were proposed. The estimated maximum amount of energy that can be recovered is around 7.44 GWh, and the maximum amount of carbon emissions saved are 446.210 tons. The evaluation of the profitability of our project integrating an energy recovery device is fair.

 Articles related

Mas Ahmad Baihaqi, Rini Nur Hasanah, Hadi Suyono    

This study proposes the use of Particle Swarm Optimization (PSO) algorithm to optimize the placement of Distributed Generation (DG) on the 20kV distribution system of Pujon feeder, which has 117 buses with the total distribution line length of 59.65 kilo... see more


Heryogka Ahmad Waritza,Gunawan Gunawan,Agus Adhi Nugroho                           DOI : 10.26623/elektrika.v15i1.5623 | Abstract views: 75 times    

The reliability of an electric power distribution network system is very important to ensure a good quality of service for consumers. The focus of this study is to find the optimal protection coordination design, topology and operating scheme for RDT03 r... see more

Revista: Elektrika

lili Tanti, Syahril Efendi, Maya Silvi Lydia, Herman Mawengkang    

Indonesia has many disaster-prone areas, natural disasters that occur in Indonesia in 2021 are 5,402 disasters. For disaster management in post-disaster areas, logistical planning is needed in the distribution of logistical assistance, it is estimated th... see more


ICEPE Conference, Engr Mian Rizwan, Dr. Lucheng Hong, Engr Safdar Rasool, Dr. Yuan Gu, Dr. Minghe Wu , Engr. Sara Bilal    

The conventional protection schemes may lead towards the inadvertent operation of the protection devices with the increased penetration of renewable energy sources based distributed generation (RES-DG) in distribution networks (DN). The miscoordination a... see more


Castellanos Vargas, Yaneth,Davila Perez, Marvin Vladimir,Fuentes Castellanos, Marlon Andrés    

The location of the plant after having carried out an evaluation of factors for both macro and micro location, will be in the municipality of Los Patios, since according to the analysis carried out it is a place with a very good industrial projection and... see more