Home  /  Mechanical  /  Vol: 7 Núm: 2 Par: 0 (2016)  /  Article
ARTICLE
TITLE

Effect of a Pipe Number on The Heat Transfer Rate For a Granit Stone Absorber Solar Collector

SUMMARY

As the fossil energy has been getting depletion, it is important to utilize alternative energies such as solar energy. An equipment that can be used for capturing and converting solar energy is solar collector. Two identical collectors used in this study were placed facing to the North with an inclination angle of 15°. The collector dimension was 0.8 m x 1 m x 0.05 m. One collector contained 5 parallel pipes and the other contained 7 parallel pipes.  The water used in the test was flowed naturally due to the gravity force from a higher tank and was adjusted using a valve fitted at the end of the collector. The water flow rates employed were 200, 250 and 300 cc/minutes and  measured using a volume meter and a stop watch. The results showed that the energy coming into the collector, energy absorbed by the absorber and water, increased with an increase in the observation time and reached the peak value at about  2.30 pm. After that, they decreased. The effect of the pipe number is significant and the performance of the collector containing 7 pipes is better than that containing 5 pipes.

 Articles related

Nsaif jasim Hadi jasim Hadi,Ahmed Atiyah Itwayya,Ameer L. Saleh,Hayder Tarar    

The age of the pipelines is a factor in increasing the potential risk to corrosion in pipelines hence reduces the safety of pipelines, and gets pipelines more likely to explosion or breakage. Thus, that will threaten the safety of individuals and the env... see more


A'rasy Fahruddin    

This research concerned the standard value of surface roughness on Computer Numerical Control (CNC) to obtain fine pipe cutting result and is more useful for company to simply recognize the appropriate standard gap in designing. Standard design used is 3... see more


Samuel Hartono,Deendarlianto Deendarlianto    

This research has been conducted study the effect of horizontal pipe length on flooding phenomenon. Observation of the flow phenomenon has used high speed camera. Working fluids for this study were water-air and the water flow was countercurrent to the a... see more


Setyo Nugroho, Achmad Arifudin Hidayatulloh    

The use of elbow or curved pipe in the installation of piping has a loss of pressure (pressure drop) which could lead the power of pump that drive the fluid and decrease the energy efficiency of the system. The pressure drop is caused by the curved shape... see more


A.A. Adhi Suryawan, Made Suarda    

The hydram pump is a motorless pump, which is its working mechanism use potential energy only. The hydram pump consists of a component called an air vessel. Until now, it is not exactly known yet what is the effect of air vessel to performance of hydram ... see more