Home  /  Electronics  /  Vol: 7 Núm: 6 Par: June (2018)  /  Article
ARTICLE
TITLE

All SiC Grid-Connected PV Supply with HF Link MPPT Converter: System Design Methodology and Development of a 20 kHz, 25 kVA Prototype

SUMMARY

Design methodology and implementation of an all SiC power semiconductor-based, grid-connected multi-string photovoltaic (PV) supply with an isolated high frequency (HF) link maximum power point tracker (MPPT) have been described. This system configuration makes possible the use of a simple and reliable two-level voltage source inverter (VSI) topology for grid connection, owing to the galvanic isolation provided by the HF transformer. This topology provides a viable alternative to the commonly used non-isolated PV supplies equipped with Si-based boost MPPT converters cascaded with relatively more complex inverter topologies, at competitive efficiency figures and a higher power density. A 20 kHz, 25 kVA prototype system was designed based on the dynamic model of the multi-string PV panels obtained from field tests. Design parameters such as input DC link capacitance, switching frequencies of MPPT converter and voltage source inverter, size and performance of HF transformer with nanocrystalline core, DC link voltage, and LCL filter of the VSI were optimized in view of the site dependent parameters such as the variation ranges of solar insolation, module surface temperature, and grid voltage. A modified synchronous reference frame control was implemented in the VSI by applying the grid voltage feedforward to the reference voltages in abc axes directly, so that zero-sequence components of grid voltages are taken into account in the case of an unbalanced grid. The system was implemented and the proposed design methodology verified satisfactorily in the field on a roof-mounted 23.7 kW multi-string PV system.

 Articles related

Elena V. Sukhova    

The effects of substitution of Fe in the boron-rich Fe–B–C alloys, containing 10.0–14.0 % B; 0.1–1.2 % C; Fe – the remainder, 5.0 % Ti, Al, or Si (in wt. %) have been studied with optical microscopy, X-ray diffractometry, scanning electron microscop... see more


Khoirun Niamah, Solichah Larasati, Raudhatul Jannah    

This research based on simulation to show impact of the power allocation on Non-Orthogonal Multiple Access (NOMA) using Successive Interference Cancellation (SIC). NOMA used superposition code (SC) on the transmitter and SIC on the receiver. NOMA has two... see more


Evawani Priscilia Sihotang, Retno Sekar, Zakiyya, Nurhayati Harahap    

Saat ini perusahaan menerima banyak permintaan dari konsumen, dimana hal tersebut membuat semua operator harus bekerja lebih keras lagi. Pertama sekali bahan baku diolah pada departemen penerimaan bahan baku. Pada departemen ini terdapat proses pencucian... see more


Maryna ??zhevnikova, Volodymyr Levenets, Oleksandr Omelnyk, Andriy Shchur    

The article deals with the influence of negative factors of working conditions on the health status of NSC KIPT personnel when working with beryllium. Beryllium and its compounds render a general toxic, allergenic and carcinogenic effect on the organism.... see more


Ida Hamidah,Sriyono Sriyono,Muhammad Nur Hudha    

The new Coronavirus (namely Covid-19) discovered in 2019 in Wuhan has sickened more than three million people in worldwide. Because Covid-19 is spreading so fast and killing so many people, it has encouraged researchers to conduct research and publish it... see more