Fuzzy logic approach for heart rate variability

SUMMARY

Intrioution. The heart rate variability (HRV) is based on measuring (time) intervals between R-peaks (of RR-intervals) of an electrocardiogram (ECG) and plotting a rhythmogram on their basis with its subsequent analysis by various mathematical methods that are classified as Time Domain (TD), Frequency Domain (FD) and Nonlinear (NM) [1, 2]. Diversity of methods and approaches to analysis of HRV is stemming from complexity and nonlinearity of the phenomenon itself, as well as from greater diversity of physiological reactions of an organism, both in normal and pathological states. Therefore, it appears relevant and important to incorporate currently existing HRV indicators and norms into a unified Fuzzy Logic (FL) methodology, which in turn will allow to integrally assess each metric and HRV results as a whole. Objective. We propose a Fuzzy Logic algorithm for incorporating into a single view of each metric, – Time Domain, Frequency Domain, Nonlinear Methods and HRV as a whole. Materials and methods. We define by FL the extent of belonging to normal state both for each distinct HRV metric – TD, FD and NM, and for a patient's HRV in general. Membership functions of any HRV index and defuzzification rules for FL scores was defined. In order to implement the proposed algorithm, specified parameters of mean values of HRV (?) indicators and their standard deviation (s) have been found in scientific publications on HRV [1, 3, 7, 8, 9, 10]. We use for FL algorithm demonstration a long-term HRV records by Massachusetts Institute of Technology - Boston’s Beth Israel Hospital (MIT-BIH) from [11], a free-access, on-line archive of physiological signals for Normal Sinus Rhythm (NSR) RR Interval, Congestive Heart Failure (CHF) RR Interval and Atrial Fibrillation (AF) Databases [12]. Conclusion. In this article, we have presented a comprehensive view of HRV by Fuzzy Logic technology and thoroughly examined the peculiarities of its application and interpretation. Of all considered examples of FL analysis, the worst result is demonstrated by a patient from the AF group, while the best one belongs to a patient from the NSR group. Difference in FL Scores between these patients from NSR and CHF groups is almost 4 times, while between patients from NSR and ?F groups it is almost 6 times. It appears especially important to implement such a design in portable medical devices for quick and easy interpretation of numerous parameters measured by them. 

 Articles related

Abdullahi Abubakar Mas’ud, Jorge Alfredo Ardila-Rey, Ricardo Albarracín, Firdaus Muhammad-Sukki and Nurul Aini Bani    

This paper compared the capabilities of the artificial neural network (ANN) and the fuzzy logic (FL) approaches for recognizing and discriminating partial discharge (PD) fault classes. The training and testing parameters for the ANN and FL comprise stati... see more

Revista: Energies

Chuanxue Song, Yulong Shao, Shixin Song, Cheng Chang, Fang Zhou, Silun Peng and Feng Xiao    

Inconsistencies that are associated with parallel-connected cells used in electric vehicles induce varied states of charge (SOCs) in each cell. Thus, loop current in the battery pack is inevitable, and this reduces overall capacity, energy utilization ra... see more

Revista: Energies

Mohamed Redha Rezoug, Rachid Chenni and Djamel Taibi    

Photovoltaic pumping is considered to be the most used application amongst other photovoltaic energy applications in isolated sites. This technology is developing with a slow progression to allow the photovoltaic system to operate at its maximum power. T... see more

Revista: Energies

Yu-Shan Cheng, Yi-Hua Liu, Holger C. Hesse, Maik Naumann, Cong Nam Truong and Andreas Jossen    

Self-consumption of household photovoltaic (PV) storage systems has become profitable for residential owners under the trends of limited feed-in power and decreasing PV feed-in tariffs. For individual PV-storage systems, the challenge mainly lies in mana... see more

Revista: Energies

Arif Budi Setiawan,Riky Dwi Puriyanto    

Sistem penerangan ruangan konvensional kurang efisien dalam penggunaan energi karena hanya menggunakan prinsip menyalakan (on) dan mematikan (off) lampu serta tidak menghiraukan pengaruh dan kontribusi dari luar atau pencahayaan matahari. Untuk mengatasi... see more