SPECTROPHOTOMETRIC DETERMINATION OF PYROCATHECOL AND PYROGALLOL BASED ON THEIR REDOX REACTION WITH IRON(III)/PHENANTHROLINE SYSTEM

https://doi.org/10.22146/ijc.21911

Mudasir Mudasir(1*), Mugiyanti Mugiyanti(2), Ngatidjo Hadipranoto(3)

(1) Department of Chemistry, Faculty of Mathematics and Natural Sciences, Gadjah Mada University, Sekip Utara, P.O. Box Bls. 21, Yogyakarta 55281
(2) Department of Chemistry, Faculty of Mathematics and Natural Sciences, Gadjah Mada University, Sekip Utara, P.O. Box Bls. 21, Yogyakarta 55281
(3) Department of Chemistry, Faculty of Mathematics and Natural Sciences, Gadjah Mada University, Sekip Utara, P.O. Box Bls. 21, Yogyakarta 55281
(*) Corresponding Author

Abstract


An analytical method for the spectrophotometric determination of some phenolic compounds, i.e.: pyrocathecol and pyrogallol based on their redox reaction with iron(III)-phenanthroline complex has been developed. These two compounds, in appropriate conditions, reduce iron(III)-phenanthroline complex to yield very stable and color-intense complex of iron(II)-phenanthroline, [Fe(phen)2]2+, whose concentration is equivalent to the amount of pyrocathecol or pyrogallol in the solution, and is easily detected by spectrophotometric method. Some parameters influencing the sensitivity of the determination were optimized. These included maximum absorption wavelength, pH of the solution, time and temperature of heatingand reagent to analyte minimum mole-ratio. Using the optimum conditions obtained, the analytical performance of the method was examined and the developed method was then applied to analyzed pyrocathecol and pyrogallol contents in several river water of Yogyakarta, Indonesia. Result of the study showed that the optimum conditions for the determination of pyrocathecol are as follows: maximum absorption wavelength (lmax) at 510 nm, pH of the solution = 4, heating time = 120 min, heating temperature = 70 0C and the minimum mole ratio of reagent to analyte is 8. On the other hand, the optimum conditions for the determination of pyrogallol are as follows: maximum absorption wavelength (lmax) at 510 nm, pH of the solution = 5, heating time = 90 min, heating temperature = 90 0C and the minimum mole ratio of reagent to analyte is 7. At the corresponding conditions of analysis, calibration curves for pyrocathecol and pyrogallol are linear in the range concentration of 0.00 - 0.16 ppm and 0.00 - 0.24 ppm, respectively. The correlation coefficients for both compounds were found to be higher than 0.998 and the detection limits went down below 0.07 ppm. It has been demonstrated that the developed method can be applied for the determination of pyrocathecol and pyrogallol contents in natural samples.


Keywords


Spectrophotometry; phenolic compounds; 1,10-phenanthroline; redox reaction

Full Text:

Full Text PDF


References

[1] Peiro, A.M., Ayllon, J.A., Peral, J. and Domenech, X., 2001, Applied Catalysis B: Environmental, 30, 359 – 373.

[2] Cooper, W.J., 1981, Chemistry in Water Reuse, Vol. 2, Ann Anbor Science Publisher Inc., Michigan, USA.

[3] Ouelette, J.R., 1998, Organic Chemistry, 2nd Ed., Prentice Hall International, New York.

[4] Jain, R.K., Aurelle, Y., 1997, Environmental Technologies and Trends, Springer Verlag, Berlin-Heidelberg, Germany.

[5] Haryono, 1997, Analisis Senyawa Fenolik dalam Air Limbah Industri Migas dengan Metode Kromatografi Cair Kinerja Tinggi, Skripsi, FMIPA UGM, Yogyakarta.

[6] Koch, S. and Ackermann, G., 1992, Talanta, 39, 687 – 691.

[7] Koch, S. Ackermann, G. and Linder, P, 1992, Talanta, 39, 693 – 696.

[8] Shriver, D.F., Atkins, P.W. and Langford, C.H., 1990, Inorganic Chemistry, Oxford University Press, Oxford.

[9] Mudasir, Yoshioka, N., and Inoue, H., Anal. Lett., 1996, 29, 2241.



DOI: https://doi.org/10.22146/ijc.21911

Article Metrics

Abstract views : 1349 | views : 3945


Copyright (c) 2010 Indonesian Journal of Chemistry

Creative Commons License
This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License.

 


Indonesian Journal of Chemistry (ISSN 1411-9420 /e-ISSN 2460-1578) - Chemistry Department, Universitas Gadjah Mada, Indonesia.

Web
Analytics View The Statistics of Indones. J. Chem.