<b>Temperature distributions in pavement and bridge slabs heated by using vertical ground-source heat pump systems</b> - doi: 10.4025/actascitechnol.v35i4.15712
Abstract
Temperature distribution which occurs in pavement and bridge slabs heated for de-icing and snow melting during cold periods is determined by using vertical ground-source heat pump (GSHP) systems with U-tube ground heat exchanger (GHE). The bridge and pavement models (slabs) for de-icing and snow melting were constructed. A three-dimensional finite element model (FEM) was developed to simulate temperature distribution of bridge slab (BS) and pavement slab (PS). The temperature distribution simulations of PS and BS were conducted numerically by computational fluid dynamics (CFD) program named ‘Fluent’. Congruence between the simulations and experimental data was determined.
Downloads
DECLARATION OF ORIGINALITY AND COPYRIGHTS
I Declare that current article is original and has not been submitted for publication, in part or in whole, to any other national or international journal.
The copyrights belong exclusively to the authors. Published content is licensed under Creative Commons Attribution 3.0 (CC BY 3.0) guidelines, which allows sharing (copy and distribution of the material in any medium or format) and adaptation (remix, transform, and build upon the material) for any purpose, even commercially, under the terms of attribution.