ARTICLE
TITLE

Monitoring Left Atrial Pressure With a Useful Epidural Catheter

SUMMARY

Background: Left atrial pressure (LAP) monitoring provides a valuable option for management of hemodynamic status in pediatric congenital heart surgery during the postoperative period.Methods: We used a Perifix Soft Tip 701 filter set catheter (B. Braun Melsungen AG 34209 Melsungen, Germany), which is commonly used for continuous epidural anesthesia. The catheter was placed into the left atrium to provide LAP monitoring. The study included 33 children, who needed LAP monitoring during and post-surgery between January 2016 and September 2017. Patients retrospectively were reviewed for ease of catheter placement, effectivity, accurate LAP, postoperative stability, and complications after removal of the catheter, including bleeding, air embolism, or thromboembolic events.Results: Patients ranged in age from 2 days to 131.27 months (Mean 11.80 days ± 25.76 days). Fifteen patients were newborn. Of the newborn patients, 39.4% (N = 13) were female. Catheters successfully were implanted in all patients, and there were no procedural complications. Left atrial catheters were removed between 1 to 12 days, with an average of 3.55 days ± 3.39 days before chest tube removal. During follow-up, patients did not suffer complications, such as thrombus formation, catheter-related infection, systemic embolism or stroke. Also, after the catheter was withdrawn, patients did not suffer from bleeding, haemodynamic deterioration, catheter retention, or require the need for intervention. During the stay in ICU, catheter nonfunction was the most frequent complication at 12.1 percent (N = 4). Conclusion: This is a simple, easy, and safe technique for wide use in congenital cardiac surgery patients.

 Articles related

Vassilios Gulielmos, Utz Kappert, Markus Eller, Heiko Sahre, Konstantin Alexiou, Christian Georgi, Joachim Nicolai, Nikolaus Hartmann    

Background: To avoid hemodynamic deterioration during tilting of the heart in off-pump surgery, we perform atrial pacing. We describe hemodynamic evaluation of this simple maneuver. Methods: Eleven consecutive patients (8 men, 3 women; age, 68.14 ± 10.3 ... see more


Dimitri Novitzky, Edward G. Izzo, Mark J. Alkire, John C. Brock    

An approach for the replacement of the distal ascending aorta-proximal arch and acute dissection is described. During the operation, the patient's entire body was continuously perfused, the aortic arch was excluded from the arterial circulation, and the ... see more


Reida El Oakley, Zakaria Al msherqi, Sai-Kiang Lim, Szu-Hee Lee, Kheng-Thye Ho, Antono Sutandar, C.N. Lee, Yean-Teng Lim    

Background: Animal studies suggest that cell transplantation, including bone marrow-derived cells, can ameliorate left ventricular remodeling following myocardial ischemia. Clinical evaluation of the potential benefits of this approach is limited by the ... see more


Donald S. Likosky, Desmond J. Donegan, Robert C. Groom, Scott A. Buchanan, Jeremy R. Morton, Cathy S. Ross, Gerald T. O.Connor    

Background: Neurologic injury is a rare yet devastating outcome of coronary artery bypass grafting surgery. Mechanisms producing both focal and global neurologic injuries include embolization, cerebral hypoperfusion, and hypotension. In this present stud... see more


Christian H. Møller, Martin A. Nørgaard, Jens P. Gøtze, Claus B. Andersen, Niels V. Olsen, Daniel A. Steinbrüchel    

We investigated the possibility of nourishing the myocardium through selective retrograde coronary venous bypass grafting (CVBG) with an off-pump technique and evaluated various methods of monitoring the physiological effects of this procedure. In a porc... see more